San Juan Watershed task D & E report step A design & cost estimate for off-farm irrigation facilities & preliminary PIA determination.
(eBook)

Book Cover
Average Rating
Published
Fresno, Calif. : Boyle Engineering Corporation, 1986.
Physical Desc
1 online resource (1 volume in various pagings).
Status

Description

Loading Description...

Also in this Series

Checking series information...

More Like This

Loading more titles like this title...

More Copies In Prospector

Loading Prospector Copies...

More Details

Format
eBook
Language
English

Notes

General Note
Report research sponsored by the State of Colorado Department of Law.
General Note
"August 1986."
General Note
Online resource lacks sheets of maps.
Description
The purpose of this task report is to present the methodology for determining practicably irrigable acreage (PIA) for the San Juan Watershed. The test for PIA requires that the revenues exceed the cost. The land under consideration when cropped and irrigated must return sufficient net positive income to pay for the costs of providing irrigation water to the farm headgate In order to determine PIA it is necessary to conceptually design an irrigation transmission system to deliver water to the farm headgate for each arable parcel. The annualized cost of the off farm irrigation water transmission system is compared to the net positive income payment capacity of the parcel.
Funding Information
BK-C22-100-04/05

Citations

APA Citation, 7th Edition (style guide)

(1986). San Juan Watershed task D & E report step A: design & cost estimate for off-farm irrigation facilities & preliminary PIA determination . Boyle Engineering Corporation.

Chicago / Turabian - Author Date Citation, 17th Edition (style guide)

1986. San Juan Watershed Task D & E Report Step A: Design & Cost Estimate for Off-farm Irrigation Facilities & Preliminary PIA Determination. Boyle Engineering Corporation.

Chicago / Turabian - Humanities (Notes and Bibliography) Citation, 17th Edition (style guide)

San Juan Watershed Task D & E Report Step A: Design & Cost Estimate for Off-farm Irrigation Facilities & Preliminary PIA Determination Boyle Engineering Corporation, 1986.

MLA Citation, 9th Edition (style guide)

San Juan Watershed Task D & E Report Step A: Design & Cost Estimate for Off-farm Irrigation Facilities & Preliminary PIA Determination Boyle Engineering Corporation, 1986.

Note! Citations contain only title, author, edition, publisher, and year published. Citations should be used as a guideline and should be double checked for accuracy. Citation formats are based on standards as of August 2021.

Staff View

Grouped Work ID
bcf71c14-55f0-b0ba-6360-dbfaff0ba56f-eng
Go To Grouped Work

Grouping Information

Grouped Work IDbcf71c14-55f0-b0ba-6360-dbfaff0ba56f-eng
Full titlesan juan watershed task d and e report step a design and cost estimate for off farm irrigation facilities and preliminary pia determination
Authorboyle engineering
Grouping Categorybook
Last Update2022-06-13 10:33:16AM
Last Indexed2024-05-04 05:04:27AM

Book Cover Information

Image Sourcedefault
First LoadedJun 23, 2022
Last UsedMay 6, 2024

Marc Record

First DetectedSep 26, 2017 12:00:00 AM
Last File Modification TimeJul 31, 2021 04:36:39 AM

MARC Record

LEADER02936nam a2200529Ii 4500
001on1004753396
003OCoLC
00520170926030312.0
006m     o  d s      
007cr |||||||||||
008170926s1986    cou     o    s000 0 eng d
035 |a (OCoLC)1004753396
040 |a DDB|b eng|e rda|c DDB|d UtOrBLW
043 |a n-us-co
049 |a DDBA
086 |a LAW1.2/SA5/1986/INTERNET
086 |a LAW1.2/SA5/1986/INTERNET|2 codocs
24500|a San Juan Watershed task D & E report step A|h [electronic resource] :|b design & cost estimate for off-farm irrigation facilities & preliminary PIA determination.
24616|a Final report San Juan Watershed
264 1|a Fresno, Calif. :|b Boyle Engineering Corporation,|c 1986.
300 |a 1 online resource (1 volume in various pagings).
336 |a text|b txt|2 rdacontent
337 |a computer|b c|2 rdamedia
338 |a online resource|b cr|2 rdacarrier
347 |a text file|2 rdaft
4901 |a Agricultural engineering study , Southern Ute & Ute Mountain, Ute Indian Reservations
500 |a Report research sponsored by the State of Colorado Department of Law.
500 |a "August 1986."
500 |a Online resource lacks sheets of maps.
520 |a The purpose of this task report is to present the methodology for determining practicably irrigable acreage (PIA) for the San Juan Watershed. The test for PIA requires that the revenues exceed the cost. The land under consideration when cropped and irrigated must return sufficient net positive income to pay for the costs of providing irrigation water to the farm headgate In order to determine PIA it is necessary to conceptually design an irrigation transmission system to deliver water to the farm headgate for each arable parcel. The annualized cost of the off farm irrigation water transmission system is compared to the net positive income payment capacity of the parcel.
536 |b BK-C22-100-04/05
5880 |a Online resource; title from PDF cover (viewed September 2017)
650 0|a Irrigation|z Colorado|z Southern Ute Indian Reservation|x Costs.
650 0|a Irrigation|z Ute Mountain Indian Reservation|x Costs.
651 0|a San Juan River Watershed (Colo.-Utah)
651 0|a Ute Mountain Indian Reservation.
651 0|a Southern Ute Indian Reservation (Colo.)
7102 |a Boyle Engineering Corporation.
7101 |a Colorado.|b Department of Law.
830 0|a Agricultural engineering study, Southern Ute & Ute Mountain, Ute Indian Reservations.
85640|u http://hdl.handle.net/11629/co:26939_law12sa51986internet.pdf|z Access online
907 |a .b10640149|b 10-24-20|c 09-26-17
945 |g 1|j 0|l csdig|o -|p $0.00|q -|r -|s j |t 0|u 0|v 0|w 0|x 0|y .i11755386|z 09-26-17
994 |a C0|b DDB
998 |a cs|b 09-26-17|c m|d a |e -|f eng|g cau|h 0|i 0
998 |a cs|b 09-26-17|c m|d a |e -|f eng|g cau|h 0|i 0
998 |a cs|b 09-26-17|c m|d a|e -|f eng|g cau|h 0|i 1